microelectrode puller sutter instruments flaming Search Results


94
World Precision Instruments microelectrode puller
Microelectrode Puller, supplied by World Precision Instruments, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microelectrode+puller+sutter+instruments+flaming/Microelectrode+Puller/pm38940922-94-24-27
Average 94 stars, based on 1 article reviews
microelectrode puller - by Bioz Stars, 2026-09
94/100 stars
  Buy from Supplier

96
Narishige inc vertical microelectrode puller
Vertical Microelectrode Puller, supplied by Narishige inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microelectrode+puller+sutter+instruments+flaming/Narishige+PC-100+Vertical+puller/pmc05577524-80-35-39
Average 96 stars, based on 1 article reviews
vertical microelectrode puller - by Bioz Stars, 2026-09
96/100 stars
  Buy from Supplier

90
RWD Life Science mp 500 microelectrode puller
Mp 500 Microelectrode Puller, supplied by RWD Life Science, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microelectrode+puller+sutter+instruments+flaming/micropipette+puller+mp+500/pmc11532233-139-6-9
Average 90 stars, based on 1 article reviews
mp 500 microelectrode puller - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

96
Sutter Instrument Company flaming brown p 87 micropipette puller
Flaming Brown P 87 Micropipette Puller, supplied by Sutter Instrument Company, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microelectrode+puller+sutter+instruments+flaming/P-97+Flaming%2FBrown+Type+Micropipette+Puller/pmc09075420__JAH3___11___e023472___s001-29-6-10
Average 96 stars, based on 1 article reviews
flaming brown p 87 micropipette puller - by Bioz Stars, 2026-09
96/100 stars
  Buy from Supplier

96
Sutter Instrument Company p 97 micropipette puller
P 97 Micropipette Puller, supplied by Sutter Instrument Company, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microelectrode+puller+sutter+instruments+flaming/P-97+Flaming%2FBrown+Type+Micropipette+Puller/pm22372824-53-6-14
Average 96 stars, based on 1 article reviews
p 97 micropipette puller - by Bioz Stars, 2026-09
96/100 stars
  Buy from Supplier

86
David Kopf Instruments vertical microelectrode puller
Fig. 3 (a–f) Carbon-fi ber <t>microelectrode</t> fabrication step by step, next step (g) is to attach the wire and tip with transparent, and (h) details of active tip. See the explanation in the text
Vertical Microelectrode Puller, supplied by David Kopf Instruments, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microelectrode+puller+sutter+instruments+flaming/pipette+puller+vertical/10__1007_slash_978___1___4939___6490___1-2441-11-18
Average 86 stars, based on 1 article reviews
vertical microelectrode puller - by Bioz Stars, 2026-09
86/100 stars
  Buy from Supplier

90
Sutter Instrument p-2000 micropipette puller
Fig. 3 (a–f) Carbon-fi ber <t>microelectrode</t> fabrication step by step, next step (g) is to attach the wire and tip with transparent, and (h) details of active tip. See the explanation in the text
P 2000 Micropipette Puller, supplied by Sutter Instrument, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microelectrode+puller+sutter+instruments+flaming/micropipette+puller/pm17959719-72-7-6
Average 90 stars, based on 1 article reviews
p-2000 micropipette puller - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Sutter Instrument laser puller
Fig. 3 (a–f) Carbon-fi ber <t>microelectrode</t> fabrication step by step, next step (g) is to attach the wire and tip with transparent, and (h) details of active tip. See the explanation in the text
Laser Puller, supplied by Sutter Instrument, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microelectrode+puller+sutter+instruments+flaming/horizontal+puller/pm29429617-318-5-7
Average 90 stars, based on 1 article reviews
laser puller - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

86
Microelectrodes Inc pipette puller
Fig. 3 (a–f) Carbon-fi ber <t>microelectrode</t> fabrication step by step, next step (g) is to attach the wire and tip with transparent, and (h) details of active tip. See the explanation in the text
Pipette Puller, supplied by Microelectrodes Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microelectrode+puller+sutter+instruments+flaming/pipette+puller/10__1074_slash_jbc__m109__067660-96-5-0
Average 86 stars, based on 1 article reviews
pipette puller - by Bioz Stars, 2026-09
86/100 stars
  Buy from Supplier

96
Narishige inc narishige pp83 microelectrode puller
Fig. 3 (a–f) Carbon-fi ber <t>microelectrode</t> fabrication step by step, next step (g) is to attach the wire and tip with transparent, and (h) details of active tip. See the explanation in the text
Narishige Pp83 Microelectrode Puller, supplied by Narishige inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microelectrode+puller+sutter+instruments+flaming/End+cap+with+stainless+steel+collar+for+%C3%B81%2E2mm+tube/pmc04579062-147-14-14
Average 96 stars, based on 1 article reviews
narishige pp83 microelectrode puller - by Bioz Stars, 2026-09
96/100 stars
  Buy from Supplier

86
Campden Instruments rhema labortechnik microelectrode puller
Fig. 3 (a–f) Carbon-fi ber <t>microelectrode</t> fabrication step by step, next step (g) is to attach the wire and tip with transparent, and (h) details of active tip. See the explanation in the text
Rhema Labortechnik Microelectrode Puller, supplied by Campden Instruments, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microelectrode+puller+sutter+instruments+flaming/labortechnik+microelectrode+puller+rhema/10__1523_slash_jneurosci__21___16___06430__2001-57-4-7
Average 86 stars, based on 1 article reviews
rhema labortechnik microelectrode puller - by Bioz Stars, 2026-09
86/100 stars
  Buy from Supplier

90
Instrumente GmbH dmz universal microelectrode puller
Fig. 3 (a–f) Carbon-fi ber <t>microelectrode</t> fabrication step by step, next step (g) is to attach the wire and tip with transparent, and (h) details of active tip. See the explanation in the text
Dmz Universal Microelectrode Puller, supplied by Instrumente GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microelectrode+puller+sutter+instruments+flaming/dmz+universal+microelectrode+puller/pm37903858-301-11-15
Average 90 stars, based on 1 article reviews
dmz universal microelectrode puller - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

Image Search Results


Fig. 3 (a–f) Carbon-fi ber microelectrode fabrication step by step, next step (g) is to attach the wire and tip with transparent, and (h) details of active tip. See the explanation in the text

Journal: Neuromethods

Article Title: In Vivo Neuropharmacology and Neurophysiology

doi: 10.1007/978-1-4939-6490-1

Figure Lengend Snippet: Fig. 3 (a–f) Carbon-fi ber microelectrode fabrication step by step, next step (g) is to attach the wire and tip with transparent, and (h) details of active tip. See the explanation in the text

Article Snippet: A borosilicate glass capillary was pulled to a tip using a vertical microelectrode puller (Needle/Pipette puller, Model 750, David Kopf Instruments, California, USA).

Techniques:

Fig. 6 ( a ) Microelectrode holder for working electrode specially designed for freely moving animals, based on a mechanical miniaturized system. The Ag/AgCl silver wire derived from a Tefl on-coated silver wire is placed on the skull surface over the dura mater and kept wet with saline-soaked pads. The auxiliary electrode is a stainless-steel screw. ( b , c ) Details of the mechanized device with a carbon-fi ber microelectrode inside

Journal: Neuromethods

Article Title: In Vivo Neuropharmacology and Neurophysiology

doi: 10.1007/978-1-4939-6490-1

Figure Lengend Snippet: Fig. 6 ( a ) Microelectrode holder for working electrode specially designed for freely moving animals, based on a mechanical miniaturized system. The Ag/AgCl silver wire derived from a Tefl on-coated silver wire is placed on the skull surface over the dura mater and kept wet with saline-soaked pads. The auxiliary electrode is a stainless-steel screw. ( b , c ) Details of the mechanized device with a carbon-fi ber microelectrode inside

Article Snippet: A borosilicate glass capillary was pulled to a tip using a vertical microelectrode puller (Needle/Pipette puller, Model 750, David Kopf Instruments, California, USA).

Techniques: Derivative Assay, Saline

Fig. 7 Schematic representation of porphyrin-based microelectrodes for NO measurement. See text for details

Journal: Neuromethods

Article Title: In Vivo Neuropharmacology and Neurophysiology

doi: 10.1007/978-1-4939-6490-1

Figure Lengend Snippet: Fig. 7 Schematic representation of porphyrin-based microelectrodes for NO measurement. See text for details

Article Snippet: A borosilicate glass capillary was pulled to a tip using a vertical microelectrode puller (Needle/Pipette puller, Model 750, David Kopf Instruments, California, USA).

Techniques:

Fig. 8 Step-by-step construction of an NO selective microelectrode , using carbon-fi ber microelectrodes as substrate. ( a ) Setup showing a porphyrin coating by electrodeposition of TMHPPNi dissolved in a 0.1 M solution of NaOH, using platinum loop and DNPV or FSCV. Note that the auxiliary and reference electrode must be con- nected together. ( b ) Voltammograms showing the coating process at about 690 mV, which is the potential at which the curve fl attens and this is considered to be when the coating process is fi nished. ( c ) Typical voltam- mogram obtained in vivo with a selective electrode NO, note that despite nafi on coating, traces of AA, DA, and 5HT remain in the voltammogram

Journal: Neuromethods

Article Title: In Vivo Neuropharmacology and Neurophysiology

doi: 10.1007/978-1-4939-6490-1

Figure Lengend Snippet: Fig. 8 Step-by-step construction of an NO selective microelectrode , using carbon-fi ber microelectrodes as substrate. ( a ) Setup showing a porphyrin coating by electrodeposition of TMHPPNi dissolved in a 0.1 M solution of NaOH, using platinum loop and DNPV or FSCV. Note that the auxiliary and reference electrode must be con- nected together. ( b ) Voltammograms showing the coating process at about 690 mV, which is the potential at which the curve fl attens and this is considered to be when the coating process is fi nished. ( c ) Typical voltam- mogram obtained in vivo with a selective electrode NO, note that despite nafi on coating, traces of AA, DA, and 5HT remain in the voltammogram

Article Snippet: A borosilicate glass capillary was pulled to a tip using a vertical microelectrode puller (Needle/Pipette puller, Model 750, David Kopf Instruments, California, USA).

Techniques: In Vivo

Fig. 9 Procedure to prepare the NO solution (0.165 mM) for microelectrode calibration . The NO gas was scrubbed through fi rst by 5 M NaOH solution and then by distilled water and stored in a sealed vial at 300 mmHg. See text for details

Journal: Neuromethods

Article Title: In Vivo Neuropharmacology and Neurophysiology

doi: 10.1007/978-1-4939-6490-1

Figure Lengend Snippet: Fig. 9 Procedure to prepare the NO solution (0.165 mM) for microelectrode calibration . The NO gas was scrubbed through fi rst by 5 M NaOH solution and then by distilled water and stored in a sealed vial at 300 mmHg. See text for details

Article Snippet: A borosilicate glass capillary was pulled to a tip using a vertical microelectrode puller (Needle/Pipette puller, Model 750, David Kopf Instruments, California, USA).

Techniques:

Fig. 1 Classical PPC equipped with an excentric microelectrode for electrical stimulation or for EEG recordings. Brain structured may also be electrically stim- ulated with the non-insulated tip of the PPC , the second electrode is attached at the animals ear [ 9 , 18 , 23 ]

Journal: Neuromethods

Article Title: In Vivo Neuropharmacology and Neurophysiology

doi: 10.1007/978-1-4939-6490-1

Figure Lengend Snippet: Fig. 1 Classical PPC equipped with an excentric microelectrode for electrical stimulation or for EEG recordings. Brain structured may also be electrically stim- ulated with the non-insulated tip of the PPC , the second electrode is attached at the animals ear [ 9 , 18 , 23 ]

Article Snippet: A borosilicate glass capillary was pulled to a tip using a vertical microelectrode puller (Needle/Pipette puller, Model 750, David Kopf Instruments, California, USA).

Techniques: